Multiparameter probe MPS-K16/Qualilog16
Call for Price
Category: Water Quality – Sensors
- Robust, pluggable multiparameter sensor made of plastic (PVC-U) for mounting up to twelve sensors (water level, temperature, conductivity, pH, redox potential, oxygen, turbidity, ammonia, nitrate, chloride, ammonium, sodium, calcium, fluoride, potassium, chlorophyll or cyano-bacteria-rhodamine WT)
- Additional electric contact gauge function combined with KLL-Q-2 mobile field laboratory
- Optimized design (Ø 89 mm, 572 mm length), usable starting from a 4″-diameter pipe
- Output: RS485 (SHWP), Option: MODBUS, SDI-12, 0/4-20 mA
- Optional: integrated, high-performance SEBA data logger Qualilog16 (for stationary use)
Benefits
Individually configurable: Depending on the measurement task at hand, the MPS-K16 can be individually equipped with a maximum of twelve water quality sensors and can detect up to 17 measurement parameters.
Simple handling: Special bayonet locks grant the users a simple and quick replacement of worn sensors. The calibration and configuration of the MPS-K16 are done by means of a special USB-RS485 interface cable in connection with SEBAConfig operation software (Windows). This will automatically detect if a probe is spent and must be replaced.
Robust: The housing of the MPS-K16 is made of durable plastic (PVC-U). The probe can thus be used even under adverse ambient conditions (e.g. landfill sites, contaminated sites).
Variable: The proven and robust SEBA-connect feature of the MPS-K16 allows both the connection to mobile handsets (SEBA electric contact meter, KLL-Q-2, Checker-2) and stationary data collectors with (UniLogCom, LogCom/FlashCom) or without data transmission (Qualilog16).
Application
- Water quality monitoring in surface waters: rivers, canals, springs, and lakes
- Groundwater: extraction wells, field measurement sites, landfill, and construction sites
- Other applications: discharge monitoring
Accessories
Data collector:
External:
Internal: Qualilog16
Electric water level gauge (KL):
Handset:
Calibration: Dual converter (USB/RS232 – RS485)
Operating software:
- SEBAConfig (Windows)
Specifications
Parameter: Water level [cm], [m]
Sensor: Relative pressure probe
Measuring principle: Capacitive with ceramic measurement cell
Measuring range: 0-2 / 1 /4/ 5/ 20/ 40/ 100 / 200m Water column or according to specification
Measuring accuracy: ± 0.1% FS
Long-term stability: ± 0.1% / year
Parameter: Water temperature [° C]
Sensor: NTC30 with polynomial linearization
Measuring Principle: NTC resistor
Measuring range: -5 – + 50 ° C
Measuring accuracy: 0.1 ° C
Resolution: 0.01 ° C
Pressure range: 0-50 bar
Parameter: Water temperature [° C]
Sensor: NTC30 with polynomial linearization
Measuring principle: NTC resistor
Measuring range: -5 – + 50 ° C
Measuring accuracy: 0.1 ° C
Resolution: 0.01 ° C
Pressure range: 0-50 bar
Parameter: Conductivity [μS / cm], [mS / cm]
Derived parameters: Solutes [g / l], salinity, density [g / l]
Sensor: 4-electrode measuring cell
Measuring range: 0-200mS / cm (total) automatic
Measuring range switching: 0-200μS / cm; 0.2-2mS / cm; 2-20 mS / cm; 20-200 mS / cm
Measuring accuracy: ± 1μS / cm at measuring range 0-200μS / cm; +/- 0.5% with measuring range 0.2-200mS
Resolution: 0.0001 mS / cm
Temperature: -5 ° C-50 ° C
Pressure range: 0-50 bar
Parameter: PH value [pH]
Sensor: Glass electrode
Measuring range: 0-14pH
Measuring accuracy: ± 0.1pH
Resolution: 0.01pH
Temperature: 0-50 ° C
Pressure range: 0-20 bar
Parameter: Redox [mV]
Sensor: Glass electrode
Measuring range: -1200mV-1200mV
Measuring accuracy:
Resolution:
- ± 10mV
- 1mV
Temperature: 0-50 ° C
Pressure range: 0-20 bar
Parameter: Oxygen [mg / l]
Derived parameters: Oxygen saturation [%]
Sensor: Clark electrode (amperometry)
Measuring range: 0-40mg
Measuring accuracy: ± 0.5% FS
Resolution: 0.01mg / l
Temperature: 0-50 ° C
Pressure range: 0-10 bar
Alternatively: Oxygen [mg / l]
Sensor:
Measuring range: 0-25mg / L (at 25 ° C, 1013hPa) 0-40mg / L (at 3 ° C, 1013hPa)
Measuring accuracy: ± 0.5% FS
Resolution: 0.001mg / l
Temperature: -5 ° C-50 ° C
Pressure range: 0-12 bar
Sensor: Turbidity [NTU]
Derived parameters: Suspended substances [mg / l] optically
Measuring range: 0-1000 NTU and 0-5000 NTU
Measuring accuracy: ± 1% of the respective end of measuring range
Resolution: ± 0.0125 % of the respective end of measuring range
Temperature: 0-50 ° C
Pressure range: 0-10bar (with wiper) 0-20bar (without wiper)
Further possible parameters for MPS-K16:
Housing Material: PVC-U
Dimension: Ø89
Length: 572mm
Protection class Probe: IP68
RS485 interface: IP67 (immersion depth with dry cartridge up to 3m, depending on cable length)
Pressure range: 0-12 bar
Outputs: RS485 (SHWP) Standard, MODBUS, SDI12, 4-20mA (option)
Communication Interface: RS485
Power supply: 4-15VDC or 8-15VDC with optical sensors
Operating temperature: Parameter-dependent
Mounting depth: Up to 1000m
Electric wire: Reinforced cable with pressure compensation line
Gore-Tex membrane, dry cartridge with Silica Gel for the protection of the pressure compensation line